preload-image

large cooling water pump of power plant ppt

blog post image blog post image

Service Water Mechanical Draft Cooling Tower Basin (400,000 gallons [1,500 m3]): Use a portable pump and the Yard connection flange to supply water to the Pool. Nuclear power plants have portable pumps located on site for the purpose of transferring water between various sources. 4.

blog post image blog post image

start up the district cooling pumps and we were invited to be present at the commissioning – from where the photos shown were taken. The Nieuwe Meer (from where the cooling water originates) is deep and the water in the lower layers of the lake is always cold (6-8 °C) making it a large, cold water reservoir.

blog post image blog post image

Oct 03, 2013· Particular power station pumps: cooling water pumps. The cooling water pumps supply large quantities of cooling water to the condenser to condense the steam into water. In a 660 MW Unit, the main cooling water pipes would be 2.0m to 2.6m diameter, and the cooling water flow would be up to 20 m3/s per Unit.

blog post image blog post image

Figure 1-2 shows the Rankine cycle on a temperature-entropy diagram for a steam power plant. The solid red lines are for a coal-fired power plant; the large-dash red lines are for a nuclear plant. The condensed steam is pressurized with a pump from Point 1 to Point 2 and is then heated up in a boiler to reach from Point 2 to Point 3.

blog post image blog post image

pump is among the most inefficient of the components that comprise a pumping system, includ-ing the motor, transmission drive, piping and valves. Hydraulic power, pump shaft power and electrical input power Hydraulic power P h = Q (m3/s) x Total head, h d - h s (m) x ρ (kg/m3) x g (m/s2) / 1000 Where h d – discharge head, h

blog post image blog post image

Cooling system Part of heat released by fuel burning in the engine cylinder passes through the cylinder walls, piston, rings, … etc. and may cause damage to the system. To keep the temperature of engine parts within safe operating limits, cooling is provided. The cooling system consists of a water source, pump and cooling towers. The pump

blog post image blog post image

Dec 22, 2009· Open Cooling system. In an open circulating water system, water from a large water body like the sea, or a river or a lake is pumped to the condenser and is returned back to the same source. Since the sea is a free and large open source of water, we …

blog post image blog post image

MHI is a leading manufacturer of power plant pumps, known for its cutting-edge research and development and manufacturing technology. Gathering expertise from all related areas, we provide various types of high-quality, reliable pumps for thermal power plants, including boiler circulating pumps, circulating water pumps and condensate pumps.

blog post image blog post image

Non-Return Water Cooling System This is suitable for large installations and where plenty of water is available. The water from a storage tank is directly supplied to the engine cylinder. The hot water is not cooled for reuse but simply discharges. The low H.P. engine, coupled with the irrigation pump is an example. Thermo-Syphone Water Cooling ...

blog post image blog post image

May 10, 2020· A down flow type surface condenser is designed to handle 110 TPH of steam, the steam enters the condenser at 0.12 kg/cm2 absolute pressure and 0.9 dryness fraction. Condensate leaves at 45 °C, calculate the quantity of cooling water required, condenser inlet and outlet cooling water temperatures are 29 °C and 37 °C respectively.

blog post image blog post image

Dec 22, 2014· CW AND ACW PUMP HOUSE 9.1 CW PUMP HOUSE CW pump specifications: Pump output flow: 35300m3 /hr Input voltage: 6.6kv Power: 3000kw Speed: 372 rpm Discharge pressure: 2 to 2.3 kg/cm2 Header pressure: 2.7 kg/cm2 In order to refresh, the cooling water is blow down is provided and at the bottom of the sump and fresh water is added as make up. In ...

blog post image blog post image

Power plant pumps . With more than 6,000 large pumps installed worldwide, GE has experience in designing, installing, and maintaining large and specialized pumps for nuclear turbine islands. Our expertise End-to-end pump solutions ... Circulating and cooling water pumps.

blog post image blog post image

EDF Energy's combined-cycle gas turbine (CCGT) power plant at Bouchain in Northern France has already earned a place in the record books. Sulzer was contracted to deliver the design and manufacture two large cooling water pumps at Bouchain power plant. The scope of Sulzer's working including the desing of the suction take.

blog post image blog post image

Answer (1 of 5): The Auxiliary cooling water pump is a part of the plant auxiliary cooling system.I will try to describe the function briefly: * The Auxiliary cooling water( ACW) pump is a pump that keeps the circulation of water in the colder side ( heat absorbing side) of a plate heat exchang...

blog post image blog post image

Jun 01, 2017· Circulating water (CW) pumps used for condenser cooling are normally the largest pumps at a power station, commonly delivering flows of 150,000 gallons per minute or higher.

blog post image blog post image

Capacity Nuclear Power Plant Large-capacity condensers with cooling area of 102,000 m2 and Fig. 2—Basic Structure of Tube Cleaning System. System consists of a ball strainer, ball recirculating pump, ball collector, ball injection nozzle, tubing, and valves. Type Cooling surface Tube Diameter Thickness Effective length No. of tubes 3-shell ...

blog post image blog post image

Jan 01, 2010· The repowering plans contemplated a significant reduction in cooling water use from the river since the current cooling system would have been replaced by …

blog post image blog post image

Example: Big Water Pump Station Figure 3 - Projected Average Day Power Usage, 2011 Projected Average Day Flow 0 200 400 600 800 1000 1200 1400 1600 1800 January February March April May June July August September October November December Month Average Power (kW)-5 10 15 20 25 30 Average Power Consumption Current Condition Pumps - 877 kW After ...

blog post image blog post image

The main advantages of incorporating a steam condenser in a steam power plant are as follows: ... • A pump to circulate the cooling water in case of a ... It requires large quantity of cooling ...

blog post image blog post image

Cooling water pumps are used for supplying heat exchangers with cooling water. Their flow rate varies depending on the heat flow to be dissipated. The required head is determined by the type of cooling system. A distinction is made between wet cooling and dry cooling processes. Range of head and flow rate The required heads for fresh water operation usually lie within 5 to 15 m. In cooling ...

blog post image blog post image

6 Geothermal power plants • Pumps for hot water production, hydrocarbon feed, condensate extraction, cooling water, brine reinjection and associated auxiliary applications 7 Pumped-storage hydro power plants • Storage pumps and power recovery turbines 6 3 2 1 5 4 7

blog post image blog post image

Chilled Water Plant Design Guide December 2009 energydesignresources

blog post image blog post image

Cooling Water Pump: ... In thermal power plants, where cooling water is in short supply, an air-cooled condenser can be used. An air-cooled condenser is, however, significantly more expensive and cannot achieve as low a steam turbine exhaust pressure (and temperature) as a water-cooled surface condenser. ... require a large area,s and have high ...

blog post image blog post image

paGE 2 | power plant Cooling and associated impacts W ater withdrawals for thermoelectric power generation were estimated in 2005 to be 201 billion gallons per day—the highest use of any industry. Most of that water is used for cooling. Power plants boil water to produce steam, which is used to spin the turbines that generate electricity.

blog post image blog post image

Nov 13, 2017· This water pump used to drag the water from inside the engine and send it to the radiator and after cooling, it sends back cold water to the engine. When the engine starts, the thermostat valve of the cooling system stays closed so that the engine water can just only flow inside the engine.

blog post image blog post image

The reactor coolant pump is a rotary machine which circulates the reactor coolant at high temperature and pressure in a PWR nuclear power plant. A reactor coolant pump consists of a vertical shaft and a single-stage suction diffuser with excellent hydraulic efficiency. MHI adopts non-contact controlled leakage system for the shaft seals to ...

blog post image blog post image

two circulating water pump trains with higher speed motors. This would increase water flow to the condensers and reduce condenser backpressure. A multi-unit power station located on a large river was concerned that the circulating water system supplying Units 1 and 2 was operating inefficiently. Flow distribution inequality, increased condenser

blog post image blog post image

Oct 05, 2010· Other key issues. Siting: The geographic location of power plants has a huge impact on cooling technology options, water availability, type of water used for cooling, and environmental impacts.Solar and geothermal power plants, for example, must be sited in areas with high solar radiation and geothermal energy, respectively—locations that may be arid and far from conventional water …

blog post image blog post image

• Cooling tower fans and pumps • Boiler feed pumps • Service water pumps • Boiler environmental control pumps/fans Case Study 1. Drives for Multiple Induced Draft Fans This 1987 power plant had four large 3800 hp boiler ID fans driven by four Load Commutated Inverters (LCI) drives and synchronous motors in each of two units.

blog post image blog post image

Cooling Tower Pumps. Whaley Products, Inc. manufactures open loop cooling towers and closed loop cooling towers at its facility in North Texas facility in Burkburnett, TX. Furthermore, Whaley designs and builds cooling tower pump tank systems and chilled water pump tanks. WPI can provide you with a pump to supply you process or application.

blog post image blog post image

Nuclear Boiling Water Power Plant Closed System Water is heated through the controlled splitting of uranium atoms in the reactor core and turns to steam. Pumps force the water through the reactor at top speed, maximizing steam production. Steam drives the turbines that turn the generator that makes electricity. Cooling water from the river ...

blog post image blog post image

In 1986, a full meltdown occurred at the Chernobyl nuclear plant located in Ukraine (formerly Soviet Union). A test was being conducted on the reactor to see how the backup water pump generators would respond to a full power outage. The control rods were fully removed. At some point, the fission chain reaction began occurring uncontrollably.

blog post image blog post image

is possible power plants can be erected at places other than that of load provided other conditions are favorable. • Water resources: For the construction and operating of power plant large volumes of water are required for the following reasons (i) To raise the steam in boiler. (ii) For cooling purpose such as in …

blog post image blog post image

Aug 31, 2018· Boiler feed pump must not only be able to supply feed water requirement; but also work as a condensate and makeup water pump when required. To ensure proper operation of these pump; feed water must be free from steam, air and insoluble solids. Parts of Boiler Feed Pump The image display a high capacity boiler feed pump used in thermal power plant.

Newsleter

Back-To-Top
Choose Your Color